CDR‑1 & CDR‑1F Installation Guide v2.014
3. Check that jumper J1 is in the OFF position. J2 should be set according to the
CDR1F’s position in the CAT-5 “chain”. If it is the nal (or only) panel in the chain
(i.e., nothing is plugged into the POWER OUT connector), set J2 to END; in all
other cases set it to MID. Carefully use tweezers or a pair of ne-nosed pliers for
this operation.
MIDENDOFF
ON
MIDENDOFF
ON
J1 Settings
End of chain Middle of chain
4. With back box: carefully position the rear metal screening box of the CDR-1F
into the back box, taking care that the CAT-5 cable(s) and PSU wiring (if used) are
not under any strain. Insert the two M3.5 raised-head screws supplied through
the xing holes in the front plate and engage them in the threaded inserts or lugs
of the back box. Tighten until the panel is neatly ush against the wall do NOT
over-tighten.
Without back box: carefully position the rear of the unit in the hole, and x the
front panel with screws of a type and length appropriate to the wall construction.
No. 6 woodscrews are satisfactory provided that timber battens are available
either side of the hole.
CDR-1F Dimensions
Vista de pagina 13